  1 SC1010_i 080926 rev.:0 reserves the right to change limits, test conditions and dimensions given in this data sheet at any time without previous notic e. SC1010 solid state relay controler card photo non-contractual description SC1010 is a solid state relay controller card. it is intended to be used in applications where high reliability is needed. this card is configurable to trigger scr?s with 20khz pulse trains synchronised with mains voltage or in permanent mode. it can be configured to start at zero crossing or random phase. control signal can be logic level refereed to card reference (high input impedance) or floating optocoupled input (low input impedance). built in power supply is feed directly from the mains either 230 v or 400 v, 50 hz. dimensions dimensions and component situation preliminary information
2 SC1010_i 080926 rev.:0 reserves the right to change limits, test conditions and dimensions given in this data sheet at any time without previous notic e. operation gate signal modes regarding gate signals, the board can operate in two different modes; ?synchronous pulse train? or ?permanent pulse train?. operation mode is jumper selectable by means of jp1 and jp2. gate pulses in synchronous pulse train mode pulse train mode selection jumper gate pulses in permanent pulse train mode - permanent pulse train mode. when in permanent pulse train mode the board produces a 20 khz pulse signal for each scr. gate losses are higher than for ?synchronous pulse train? mode. - synchronous pulse train mode. when in synchronous pulse train mode the board produces 20 khz pulse trains synchronised and in phase with the mains voltage for each scr. this operation mode is recommended since commutation and gate losses are reduced.
3 SC1010_i 080926 rev.:0 reserves the right to change limits, test conditions and dimensions given in this data sheet at any time without previous notic e. gate pulses and load voltage in ?random phase start? mode start mode selection jumper starting modes regarding starting, the board can operate in two different modes; ?zero crossing start? or ?random phase start?. start mode is jumper selectable by means of jp3. starting mode only affects at the first cycle after a start control signal is applied. - zero crossing start mode. when in ?zero crossing? start mode, first cycle of load voltage always start at zero cross of the mains voltage. - random phase start mode when in ?random phase? start mode, voltage is applied to the load at the moment that control signal is applied. gate pulses and load voltage in ?zero crossing start? mode
4 SC1010_i 080926 rev.:0 reserves the right to change limits, test conditions and dimensions given in this data sheet at any time without previous notic e. control signal input type of control signal is jumper selectable between ?logic level? or opto-isolated. logic level input is intended to be controlled directly from a logic signal source (plc, microcontroler, etc.). it is advised logic level circuits are high impedance, so attention must be paid to avoid undesirable interference. shielded lines must be used for control signals. opto-isolated mode requires a control signal source capable of deliver at least 5ma at 15v. in this mode 5.22k ? input impedance helps to prevent interference influence, nevertheless shielding is suggested. a mechanical external switch can be used but optocoupled input mode must be selected since a high impedance open circuit can produce undesireable operation. since the switch is feeded form internal power suply, isolation is not achievable in this mode. control signal wiring control signal level jumper selection
5 SC1010_i 080926 rev.:0 reserves the right to change limits, test conditions and dimensions given in this data sheet at any time without previous notic e. synchronism signal synchronous pulse train mode requires to detect line-neutral mains voltage, this must be connected to j7 connector. see complete connection diagram at the end of application manual. maximum voltage for synchronism signal is 400 vrms !!! internal supply power internal supply is feed at 230 v or 400 v 50 hz. power must be connected to j6 connector. 0v 230v 400v control signal 12 v output signal gnd - + synchro voltage f n k 1 g 1 g 2 k 2 start mode jumper pulse train mode jumpers special application jumper don?t use it !!! power led control signal input mode output enabled led output disable led board components
6 SC1010_i 080926 rev.:0 reserves the right to change limits, test conditions and dimensions given in this data sheet at any time without previous notic e. t 1 t 2 v ln load 0v 230v 400v - + control signal application example ordering information order the standard version as SC1010 a high voltage version, capable to operate at 700 vrms, is available on request (SC1010h).
7 SC1010_i 080926 rev.:0 reserves the right to change limits, test conditions and dimensions given in this data sheet at any time without previous notic e. notice: the technical data are to specify components, not to guarantee their properties.n o warranty or guarantee expressed or implied is made regarding delivery or performance . the company reserves the right to alter without prior notice the specification of any product. information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. it is the user?s responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that an y publication or data used is up to date. all brand names and product names used in this publication are trademarks, registered trademarks or trade names of their respective owners. datasheet annotations : semicode electronica annotate datasheets in the top left hard corner of the front page, to indicate product status. the annotations are as follows: tentative information : this is the most tentative form of information and represents a very preliminary specification. no actual design work on the product has been started. preliminary information : the product is in design and development. the datasheet represents the product as it is understood but details may change. advance information : the product design is complete and final characterisation for volume production is well in hand. no annotation : the product parameters are fixed and the product is available to datasheet specification. ? semicode electronica 2008. technical documentation ? not for resale semicode electronica offers to the market a comprehensive range of products from recognized manufacturers at the best price/ quality relationship, this products are provided with a basic reference code that allows maintaining the same product reference even if the original device manufacturer is replaced. semicode product reference has to be considered as a generic brand. seeking the market needs and trends, we are constantly increasing the product portfolio with new products and suppliers, please ask for the updated information available to our local contacts. semicode products include semiconductors, passive components and accessories focused in power electronics market. cost effective products


▲Up To Search▲   

 
Price & Availability of SC1010

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X